model:HX-3S-F100AOvercharge voltage range:4.28v±0.05v
size:70*60*8.5mmOver-discharge voltage range:2.5±0.05v
Upper limit working current:100A(Pay attention to heat)Operating temperature:-40—+50°C
Upper limit instantaneous current:100-120AStorage conditions:-40– +80°C
Quiescent current: less than30uAEffective life: greater than30000hour
Internal resistance: less than300mΩShort circuit protection: protection, delay self-recovery.
Equilibrium current:65Milliamp
Charging voltage:12.6V-13VMaximum charging current:10A